10 - IS THERE A PROBLEM ?
Problems Possible causes Solutions
Water runs through the holes in the
The boiler is too full.
Do not fill the boiler right up to
soleplate. the top.
The thermostat is not working:
Contact an Approved Service
the temperature is always too Centre.
low.
You are using the steam control
Wait for the iron’s thermostat
button before the iron is hot. light to go out before activating
the steam control button.
You are using too much steam on
Wait for the iron’s thermostat
too low a temperature. light to come on and go off
again before activating the steam
control button.
Depending on the model:
Decrease the steam output while
ironing at low temperature
(control dial on base unit).
The water has condensed in the
Press the steam control button away
pipes because you are using steam
from your ironing board until the
for the first time or you have not the iron produces steam.
used it for some time.
White streaks come through the holes
Your boiler has a build-up of scale
R
inse out the boiler after every
in the soleplate. because it is not rinsed out regularly. 10 uses. If your water is hard,
increase the frequency.
Brown streaks come through the holes
You are using chemical descaling
Never add this type of product in
in the soleplate and stain the linen. agents or additives in the water for the boiler (see our recommenda-
ironing. tions regarding water to be used).
You linen is not rinsed sufficiently
Ensure linen is rinsed thoroughly
or you have ironed a new garment to remove any soap deposits or
before washing it. chemicals on new garments which
have been sucked up by the iron.
The soleplate is dirty or brown and may
You are ironing at too high a
See our recommendations regarding
stain the linen. temperature. temperature control setting.
You are using starch.
Always spray starch onto the reverse
side of the fabric to be ironed.
There is little or no steam.
The boiler is empty
F
ill the boiler.
The boiler is not yet ready.
After switching on, wait for the
steam indicator light to go out
(after 8 mins.).
Depending on the model: Depending on the model
:
Steam output is set at minimum.
Increase steam output (control
dial on base unit).
Steam escapes from the boiler cap.
Cap screwed on incorrectly.
Screw the cap back on.
The seal on the cap is damaged
Change the cap seal (spare seals
supplied with the steam generator
in the box).
Steam escapes under the appliance.
The appliance is faulty.
Stop using the generator and
contact an Approved Service
Centre.
Never dismantle your iron: always take it to an Approved Service Centre.