Sterling 60 cfm Clothes Dryer User Manual


 
15, 30, & 60 cfm Compact Dryers 32
WARNING! Handling desiccant material is HAZARDOUS.
Wear an N-100 type safety filter mask or equivalent to avoid prolonged
breathing of desiccant dust. Wear safety goggles and gloves to avoid
contact with eyes and skin.
Handle with adequate ventilation.
Wash hands thoroughly after handling.
+ FIRST AID +
In case of eye contact, immediately flush eyes
with plenty of water for at least 15 minutes.
SEE A PHYSICIAN IMMEDIATELY IF IRRITATION PERSISTS.
Replacing Worn Desiccant
Caution! DESICCANT BEDS ARE HOT DURING OPERATION.
To avoid burn hazard, make sure desiccant beds are sufficiently cool
before replacing worn desiccant.
To access the Desiccant Bed:
1. Disconnect electrical power to the dryer.
2. Using a 1/8” Allen wrench, remove the 10-24 button head screws holding the top,
back and side panels to the frame and back of the dryer.
3. Disconnect the three (3) plugs for the valve motor, switch, and blower (15 cfm only)
4. Remove four (4) nuts at each corner of the top casting.
5. Disconnect all hoses and dew point air lines.
6. Pickup and place the top casting in a safe place.
7. Using a 1/8” Allen wrench, remove the four (4) 10-32 button screws holding the
desiccant cover to the canister.
8. Remove the cover.
9. Pickup the desiccant can and turn it upside down over an empty container to remove
all desiccant.
10. Dispose of properly using MSDS sheet.