PROBLEM
Power On light does not illuminate when
timer knob is pulled out.
Lid locked light does not illuminate during
spin cycle.
Water does not enter the clothes washer.
Water flows continuously.
Washer does not agitate.
CAUSE
Clothes washer not plugged in.
Electrical outlet does not have AC power.
Light is burned out.
Lid is not fully closed.
Microprocessor did not properly boot up.
Lid lock assembly has failed.
Motor control circuit board defective.
Water on circuit board.
Polarity is incorrect at receptacle.
Low voltage on inverter system
Light has burned out
Water supply turned off.
Screens in water inlet valve are plugged.
Water valve has failed.
Pressure switch has failed.
Water level switch has failed.
Water level switch hung up between high
and low.
Drain hose is not in stand pipe.
Pressure switch has failed.
Water level switch has failed.
Pressure switch tube is disconnected from
pressure switch.
Plugged pressure switch tube.
Motor control board has failed.
Motor has failed.
Drive belt has broken or come off the pulley.
J1 connector on motor control board is not
making contact.
Washer plugged into “Green Plug.”
Poor connection on timer plug.
CORRECTIVE ACTION
Plug power cord into properly grounded
receptacle.
Check fuse or circuit breaker.
Replace light.
Close lid completely.
Reset microprocessor, unplug machine for a
minimum of 30 seconds and plug back in.
Replace lid lock assembly.
Check inputs to circuit board.
Dry board.
Call electrician and correct.
Take inverter out of sleep mode and reset
microprocessor, unplug machine for a
minimum of 30 seconds and plug back in.
Replace light.
Turn water on.
Clean screens.
Replace water valve.
Replace pressure switch.
Replace water level switch.
Move switch to correct position.
Place hose in stand pipe and secure.
Replace pressure switch.
Replace water level switch.
Connect pressure tube.
Remove obstruction.
Check fuse on circuit board.
Replace motor.
Replace belt or reinstall drive belt.
Reset connector on board.
Do not use. Remove from circuit.
Reseat connector.
TROUBLESHOOTING