Electrical Requirements
No independent external power source or supply
connection is necessary. Power to operate the 24 Volt
fire suppression system is from the rear junction/
contactor box.
Auxiliary Alarm
During tumbler installation, you have the option to
connect a separate alarm system to this auxiliary
output. Use of the auxiliary output is not required for
the fire suppression system to operate, but may be used
for additional protection.
NOTE: The auxiliary output is activated during
fire suppression system maintenance test sequence.
Consider this fact prior to your system test every
three months. (Example: If the external system uses
the auxiliary output to call the fire department,
inform the fire department before and after the fire
suppression system maintenance test.)
Gas Requirements
Natural Gas and Liquefied Petroleum
IMPORTANT: Any product revisions or
conversions must be made by the Manufacturer’s
Authorized Dealers, Distributors, or local service
personnel.
IMPORTANT: The tumbler must be isolated
from
the gas supply piping system by closing its
individual manual shut-off valve during any
pressure testing of the gas supply piping system at
test pressure equal to or less than
3.45 kPa,
34.5 mbar (0.5 psi).
IMPORTANT: The tumbler and its manually
operated appliance gas valve must be disconnected
from the gas supply piping system during any
pressure testing of that system at test pressures in
excess of
3.45 kPa, 34.5 mbar (0.5 psi).
IMPORTANT: The installation must comply with
local codes.
NOTE: This manual is only a supplement. Refer to
installation/operation manual for full instructions.
European Gas
Electrical power must be provided to
tumbler at all times. The fire suppression
system will be inoperative if the main
electrical power supply is disconnected.
W690
WARNING
To reduce the risk of fire or explosion, DO
NOT CONNECT THE GAS LINE TO THE
TUMBLER IF THE GAS SERVICE IS NOT
THE SAME AS THAT SPECIFIED ON THE
TUMBLER SERIAL PLATE! It will first be
necessary to convert the gas burner
orifice and gas valve. Appropriate
conversion kits are available.
W060
WARNING
To reduce the risk of fire or explosion, if
the tumbler is to be connected to
Liquefied Petroleum (L.P.) gas, a vent to
the outdoors must be provided in the room
where the tumbler is installed.
W062
WARNING
WARNING
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
Disconnect electric power to the
tumbler before servicing.
Close gas shut-off valve to gas tumbler
before servicing.
Close steam valve to steam tumbler
before servicing.
Never start the tumbler with any guards/
panels removed.
Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
tumbler is properly grounded.
W002