Installation
13
801516
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Grounding Instructions
The washer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. The washer is equipped
with a cord having an equipment-grounding conductor
and a 3-prong grounding plug. The plug must be
plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
DO NOT modify the plug provided with the washer –
if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
NOTE: Have a qualified electrician check the
polarity of the wall receptacle. If a voltage reading
is measured other than that illustrated, the
qualified electrician should correct the problem.
Figure 16
DO NOT OPERATE OTHER APPLIANCES ON
THE SAME CIRCUIT. DO NOT OVERLOAD
CIRCUITS!
Do not operate both a washer and gas dryer on the
same circuit. Use separately fused 15 Amp circuits.
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the washer to the
electric power source.
W082
WARNING
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the washer is properly
grounded.
W216
This unit is equipped with a three-prong
(grounding) plug for your protection
against shock hazard and should be
plugged directly into a properly grounded
three-prong receptacle. Do not cut or
remove the grounding prong from this
plug.
W213
WARNING
D799I
1 L1
2 Ground
3 Neutral Side
4 Round Grounding Prong
5 Neutral
1
3
4
2
120 ± 12
V.A.C.
0
V.A.C.
120 + 12
V.A.C.
STANDARD 120 VOLT, 60 HERTZ, 3-WIRE
EFFECTIVELY GROUNDED CIRCUIT
5
To reduce the risk of electric shock or fire,
DO NOT use an extension cord or an
adapter to connect the washer to the
electrical power source.
W031
WARNING