Speed Queen AM07-500 Washer User Manual


 
T
opload
W
asher
Coin Slide-Op Control Panel
NetMaster® Control Panel
Features: User selectable options for hot, warm or cold wash
temperatures. Two speeds with normal/gentle wash and slow/fast
extract. Six total cycles with three “water saver” cycles and three
regular selections with LEDs. MEF of 1.26 and Water Factor of 9.5.
Micro-DISPLAY Control Panel (MDC)
Features: Vacuum Fluorescent Display for vend price and cycle
time countdown. Touch Pad Control with LEDs. Three Temperature
Selections for hot, warm or cold water. Three Fabric Selections for
Normal, Permanent Press or Delicate. Regular 12 lb extra-large
capacity with 3 lb small load option. Push-to-Start activation.
MEF of 1.34 and Water Factor of 9.4.
Features: LED Digital Display for vend price and cycle time countdown.
Touch Pad Control with LED. Four Fabric Cycle Selections for
Normal/Hot, Normal/Warm, Permanent Press/Warm, Delicate/Cold.
Push-to-Start activation. MEF of 1.50 and Water Factor of 8.8.
WATER MANAGER ADVANTAGES
NETMASTER CYCLE DEFAULT AND PROGRAMMING
Feature Default Setting Options
Wash Time 10 Minutes 0–15 Minutes
Deep Rinse 4 Minutes 0–15 Minutes
Spin 6 Minutes 0–15 Minutes
Vend Price $1.00 $0.25 - $655
Fabric Selector Perm Press Normal or Delicate
Temp Selector Warm Hot or Cold
Two-Speed Cycle Operation
Wash/Rinse Spin/Extract
Cycle Action First Rinse Final Spin
Normal Normal High High
Perm Press** Normal Low High
Delicate Gentle Low High
Two-speed wash and spin cycles. **Standard setting.
NetMaster and MDC models are available with card or coin start operation.
World’s Leading Supplier of Commercial Laundry Equipment
www.speedqueen.com
AM07-500
• High efficiency automatic washers are U.S. DOE
compliant to 2007 commercial washer standards
for energy and water.
• Special multi-housing cycle for superior washability
– Extended wash, rinse and spin times
– Reduced spray rinse to save water
• Low average hot water usage per cycle
– Cold water rinses (factory set)
NetMaster Topload DOE “J1” Testing
Water Total Water DOE
Temp Hot Cold Consumption Cycle %
Hot 14.0 15.7 29.7 Gal 14%
Warm 5.4 24.3 29.7 Gal 49%
Cold 0.0 29.7 29.7 Gal 37%
Average Hot Water Per Cycle 4.61 Gal
* Water usages may vary for your particular application.
Coin Slide Topload DOE “J1” Testing
Water Total Water DOE
Temp Hot Cold Consumption Cycle %
Hot 15.1 11.0 26.1 Gal 14%
Warm 4.8 21.3 26.1 Gal 49%
Cold 0.0 26.1 26.1 Gal 37%
Average Hot Water Per Cycle 4.48 Gal
* Water usages may vary for your particular application.
MDC Topload DOE “J1” Testing
Water Total Water DOE
Temp Hot Cold Consumption Cycle %
Hot 9.1 14.6 23.7 Gal 14%
Warm 3.5 20.2 23.7 Gal 49%
Cold 0.0 23.7 23.7 Gal 37%
Average Hot Water Per Cycle 2.99 Gal
* Water usages may vary for your particular application.
Operational Efficiencies