PA235 LEVEL ATTENUATOR
The PA235 provides you with volume control when you are connecting
earphones to airplane seat outputs. It is intended only for airline use. It is not
intended for use with other audio sources.
To use the PA235:
Connect the 1/8-inch jack on the earphones to the female jack on the
PA235.
Turn the PA235 volume down completely (toward – ).
Connect the PA235 to the 1/8-inch audio output of the airplane seat.
Insert the earphones into your ears (see Inserting the Earphones)
Turn the volume on the PA235 up slightly (toward +).
Adjust the seat volume as follows:
If the audio is distorted, turn down the volume at the seat.
If there is no distortion, but there is background noise, turn up the
seat volume.
Adjust the PA235 volume to a comfortable level.
NOTE: the program may be interrupted by messages from the pilot that
are much louder. To avoid discomfort, keep the overall volume just loud
enough for listening enjoyment.
1.
2.
3.
4.
5.
6.
•
•
7.
CUSTOM EARPHONE SLEEVES
Those who use earphones regularly for extended periods of time often find
custom-fit molded sleeves offer the best comfort and sound isolation.
Ask a Hearing Health Care Professional about creating custom molded sleeves
for your earphones. For more information, contact:
FURNISHED ACCESSORIES
Level attenuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PA235
Carrying pouch . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95A2259
Fit Kit w/cleaning tool . . . . . . . . . . . . . . . . . . . . . . . . 90XJ1371
Triple flange sleeves . . . . . . . . . . . . . . . . . . . . . . . . .90WX1371
Plug adapter — 1/8” to 1/4” . . . . . . . . . . . . . . . . . . .PA234
REPLACEMENT PARTS
Bag of 20 foam sleeves . . . . . . . . . . . . . . . . . . . . . . .PA750
Bag of 500 foam sleeves . . . . . . . . . . . . . . . . . . . . . .PA754
Bag of 10 clear flex sleeves:
small
. . . . . . . . . . . . . . . .PA756S
medium
. . . . . . . . . . . . . .PA756M
large . . . . . . . . . . . . . . . . .PA756L
Bag of 10 soft flex sleeves:
small
. . . . . . . . . . . . . . . .PA758S
medium
. . . . . . . . . . . . . .PA758M
large . . . . . . . . . . . . . . . . .PA758L
SAFE USE
Use a slow twisting motion to remove the earphones. Never pull
on the earphone cord.
Warning: If a sleeve becomes lodged in your ear, seek skilled
medical assistance to remove the sleeve. Damage to the ear
may be caused by non-professionals attempting to remove the
sleeve.
Prior to inserting the earphone, always recheck the sleeve to
make sure it is firmly attached to the nozzle.
Turn up the volume control only far enough to hear properly.
Ringing in the ears may indicate that the volume level is too high.
Try lowering the volume.
If you connect these earphones to an airplane’s sound system,
listen at low levels so that loud messages from the pilot do not
cause discomfort.
Have your ears checked by an audiologist on a regular basis. If
you experience wax buildup, discontinue use until an audiologist
has examined your ears.
Stop using the earphones if they are causing great discomfort or
infection.
Sensaphonics Hearing Conservation Toll Free: (877) 848-1714
660 N. Milwaukee Avenue
In Chicago: (312) 432-1714
Chicago, IL 60622
e-mail: saveyourears@sensaphonics.com
www.sensaphonics.com
MAINTENANCE
Careful maintenance ensures a tight seal between the sleeve and
nozzle, improving sound quality and product safety.
Keep the earphones and sleeves as clean and dry as possible.
Do not expose earphones to extreme temperatures.
Wipe the earphones and sleeves with mild antiseptic to avoid
infections. Do not use alcohol-based disinfectants.
CERTIFICATION
Eligible to bear CE marking.
Conforms to European EMC Directive 89/336/EEC.
Meets applicable tests and performance criteria in European Standard
EN 55103 (1996) Parts 1 and 2, for residential (E1) and light industrial (E2)
environments.
TECHNICAL SPECIFICATIONS
Transducer type Dual low mass/high energy
Sensitivity (at 1kHz) 122 dB SPL/mW
Impedance (at 1kHz) 110 Ω
Output connector Gold-plated 3.5 mm (1/8-inch) stereo plug
Cable length 155 cm (61”)
Net weight 31 g (1.1 oz.)
Operational temperature -18° C to 57° C (0° F to 135° F)
Storage temperature -29° C to 74° C (-20° F to 165° F)