Samsung DV42H5400GF Clothes Dryer User Manual


 
7
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
COMPONENT TESTING PROCEDURES
Component Electrical Testing (with ohmmeter)
Thermistor resistance 10K Ω @ 25°C 77°F
Thermostat 1 resistance < 1Ω
Thermostat 3 resistance < 1Ω
- If resistance is infinity, replace thermostat 3.
Thermostat 2 resistance < 1Ω
- If resistance is infinity, replace thermostat 2.
[
DUAL
] Heater resistance 13 Ω (PIN 2-3) Heater
resistance 34 Ω (PIN 1-2)
- If resistance is infinity, replace Heater.
[
SINGLE
] Heater resistance 10 Ω (PIN 1-3)
- If resistance is infinity, replace Heater.
1
2
3
Measure resistance of the following terminal
1) Door switch : off
Terminal : “COM” - “NC” (1-3) < 1Ω
Terminal : “COM” - “NO” (1-2) : ∞ Ω
2) Door switch : On
Terminal : “COM” - “NC” (1-3) : ∞ Ω
Terminal : “COM” - “NO” (1-2) < 1Ω
Belt Cut-off S/W
- Lever open: Resistance value < 1Ω
- Lever push: Resistance value : ∞ Ω
Lamp resistance : ∞ Ω, (-) : BLU, (+) : WHT
Motor (Electronic & GAS)
Contacts
Function 1M 2M 3M 5M 6M
Start
Run
= Contact closed
Centrifugal Switch (Motor)
2.88Ω between
Pin# 3 and 4
3.5Ω between
Pin# 4 and 5
Technical_information-03382A_EN_131209.indd 7 2013-12-09 �� 5:37:33