Risk of Electric Shock:
When local codes allow, the dryer electrical supply may be connected by means of a new power
supply cord kit, marked for use with a dryer, that is U.L. listed and rated at a minimum of120/240
volts, 30-ampere with three No. 10 copper wire conductors terminated with closed loop
terminals, open-end spade lugs with turned up ends, or with tinned leads.
Do not reuse a power supply cord from an old dryer. The power cord electric supply wiring
must be supported at the dryer cabinet by a suitable UL-listed strain relief.
Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit
grounding through the neutral conductor. (Use a 4-prong plug for a 4 wire receptacle, NEMA
type 14-30R.)
Electric models – Canada Only
A 120/240 volt, 60 Hz AC approved electrical service fused through a 30-ampere fuse or
circuit breaker on both sides of the line is required.
All Canadian models are shipped with the power cord attached. The power cord should be
plugged into a 30-ampere receptacle.
It is not permissible to convert a dryer in Canada to 208 volts.
REPLACEMENT PARTS AND ACCESSORIES
If your dryer requires replacement parts or accessories, contact the dealer from whom you purchased your
dryer or the SAMSUNG customer care center at 1-800-SAMSUNG (726-7864).
TOOLS NEEDED FOR INSTALLATION
Gather the required tools and parts before starting the installation.
Read and follow the instructions provided with any tools listed here.
Tools and Parts
Pliers Cutting knife Pipe wrench (gas only) Nut drivers
Level Phillips Screwdriver Duct tape Wrench