9DM 253/273/293
Vapodur
®
Valve
The patented Vapodur
®
valve ensures that the opening which allows
the water to drip from the water tank into the steam chamber remains
unaffected by hard water deposits.
To ensure your iron continues to steam efficiently the valve MUST be
opened and closed a few times. This is done by moving the variable
steam control left to right a few times every time you finish ironing.
Steam Chamber Cleaning Function
This function allows loose mineral deposits and other impurities
that build up inside the iron to be flushed out. This type of self
cleaning only needs to be carried out occasionally and never
more than once a month.
˾
Fill the iron with cold tap water and set
variable steam to min.
˾
Stand on heel and plug in.
˾
Set thermostat dial to maximum
position.
˾
When the iron reaches the correct
temperature, indicator light will go out,
unplug iron.
˾
Hold iron horizontally over the sink with
soleplate pointing away from body.
˾
Press and hold down the self clean
button for about 1 minute.
WARNING: Doing this will cause steam and hot water to be
ejected from the soleplate. Take all proper precautions and hold
iron away from body.
˾
Move the iron gently back and forth and side to side until all water
has run through.
˾
Carefully wipe all water and material from the soleplate with an old
folded towel, as the water and minerals can stain the soleplate
(although this has no effect on glide or performance).
WARNING: Iron and soleplate may still be hot, exercise care while
wiping.
˾
Place iron on heel and leave to cool. Turn temperature dial to
minimum.
˾
IMPORTANT: before using the iron after self cleaning, test steam
and burst of steam on an old towel or cloth to ensure all loose
material has been removed from the iron.