Raypak LAUNDRY-PAK Washer/Dryer User Manual


 
Boiler
Model
Number
514
624
724
824
926
1083
1178
1287
1414
1571
1758
(2) 926
(2) 1083
(2) 1178
(2) 1287
(2) 1414
(2) 1571
(2) 1758
Temperature Rise
80°F 90°F 100°F
Gallons per Hour
636 565 508
779 692 623
902 802 722
1025 911 820
1195 1062 956
1397 1242 1118
1519 1350 1215
1661 1476 1328
1823 1620 1458
2025 1800 1620
2268 2016 1815
2609 2319 2087
3105 2760 2484
3727 3313 2982
4348 3865 3479
4970 4418 3976
Boiler
Model
Number
514
624
724
824
962
1125
1223
1336
1468
1631
1826
2100
2500
3001
3500
4001
Temperature Rise
80°F 90°F 100°F
Gallons per Hour
636 565 508
779 692 623
902 802 722
1025 911 820
1150 1023 920
1346 1196 1076
1464 1301 1171
1599 1421 1279
1756 1560 1404
1951 1734 1560
2184 1941 1747
2300 2046 1840
2692 2392 2152
2928 2602 2342
3198 2842 2558
3512 3120 2808
3902 3468 3120
4368 3882 3494
235 30 x 80
335 36 x 80
390 42 x 72
534 42 x 92
684 54 x 78
803 54 x 90
922 54 x 102
1164 60 x 105
Feet
HP Head
0.25 7.0
7.2
9.3
0.33 11.7
10.5
0.75 16.0
16.2
17.5
0.75 18.0
19.0
19.7
0.33 10.5
1.00 16.6
0.75 16.0
0.75 16.2
2.00 23.6
0.75 17.5
18.0
2.00 24.8
0.75 19.0
2.00 25.5
0.75 19.7
2.00 26.6
Number Gal Total GPH
Washers /Cycle /Cycle
_______ x _______ = _______
_______ x _______ = _______
_______ x _______ = _______
_______ x _______ = _______
_______ x _______ = _______
Total GPH ________
Multiply by # cycle/hour x _______
TOTAL DEMAND GPH _______
Selection:
Boiler: W1 - _______
Tank: _______ gallons
Sizing:
1. Calculate the hot water demand:
Number of machines x gallons per
load x number of cycles per hour
= GPH required.
2. Enter chart at Temperature
Rise find the GPH closest to,
but not less than, GPH
calculated.
3. Select the water heater, tank and
circulator recommended.
For complete and detailed piping diagram see Drawing 8054
Normal
Capacity
Gallons
Diameter
X
Length
Type WH Indoor Water Heater Type WH Outdoor Water Heater Tank Pump*
*Based on 5-15grains per gallon hardness. Feet Head is based on equivalent length of pipe, valve and fittings between water heater and
tank placed five (5) feet apart. Raypak, Inc. reserves the right to make product changes or improvements at any time without notice.
©RAYPAK, INC., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725
Litho USA
Sample piping diagram showing one water heater and one tank.
For two water heaters and one tank see Drawing 8069.