Maytag W10557650B Clothes Dryer User Manual


 
16
4-Wire Direct Wire Connection
Direct Wire Connection
1. Prepare your 4-wire cable
for direct connection
1"
(25 mm)
3
1
2
"
(89 mm)
5"
(127 mm)
2. Remove neutral ground wire
B
F
A
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit 3-wire connections.
Remove the neutral ground wire (white) (F) located inside the
dryer cabinet, behind the external ground conductor screw (A).
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 1
1
/
2
" (38 mm)
from remaining 3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
3-wire direct connection:
Go to “3-Wire Direct Connection”
on page 17.
4-wire direct connection:
Go to “4-Wire Direct Connection”
on this page.
If your wiring looks like this:
4. Connect remaining wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Replace the
terminal block cover on the back of the dryer.
Tighten strain
relief nut. Now, go to “Venting Requirements.”
3. Connect power supply cable wire
D
E
A
B
Place hooked end of ground wire (E) (green
or bare) of power supply cord under external
ground conductor screw (A). Squeeze
hooked end together and tighten screw.
Connect hooked end of neutral wire (D)
(white or center wire) of power supply cord
under center screw (B) of the terminal block.
Squeeze hooked end together and tighten screw.
If your wiring looks like this: