Maytag MDG76PC Clothes Dryer User Manual


 
18 Maytag Co. 113184-7
GAS ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
NOTES: A.
B.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify
correct breaker size according to appliance amp draw rating and type of breaker used.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz 50 Hz
120 1ø 2 13.0 *2020
208 1ø 27.6 *1515
230 1ø 2 8.0 * 15 15
240 1ø 27.0 *1515
208 3ø 34.7 *1515
230 3ø 3 4.7 * 15 15
240 3ø 34.9 *1515
380 3ø 4** 2.9 * 15 15
400 3ø 4** 3.1 * 15 15
416 3ø 4** 3.1 * 15 15
460 3ø 32.8 *1515
480 3ø 32.8 *1515
2. Electrical Service Specifications
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the
factory.
* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes. 8/8/05
** 3-Wire is available.
3. Grounding
A ground (earth) connection must be provided and installed in accordance with state and local codes. In
the absence of these codes, grounding must conform to applicable requirements of the National Electrical
Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable
Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The
ground connection may be to a proven earth ground at the location service panel.
For added personal safety, when possible, it is suggested that a separate ground wire (no. 18 minimum) be
connected from the ground connection of the dryer to a grounded cold water pipe. DO NOT ground to a
gas pipe or hot water pipe. The grounded cold water pipe must have metal-to-metal connection ALL the
way to the electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic,
rubber, or other insulating connectors, they must be jumped out with no. 4 copper wire and securely
clamped to bare metal at both ends.
IMPORTANT: For personal safety and proper operation, the dryer must be grounded.
Provisions are made for ground connection in each dryer at the electrical service connection area.