Maytag MDG31 Clothes Dryer User Manual


 
18 Maytag Co. 113430-3
29/06
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz 50 Hz
MDG31
120 2 10.3 15
200 2 8.7 8.8 15
208 2 8.4 15
220 2 8.1 15
230 2 7.8 15
240 2 7.7 15
MDG51
120 2 15.6 20
200 2 10.5 20
208 2 10.5 20
220 2 10.0 20
240 2 9.7 20
220 2 10.7 20
230 2 10.8 20
MDG77
120 2 15.6 20
200 2 10.5 20
208 2 10.5 20
220 2 10.0 20
240 2 9.7 20
220 2 10.7 20
230 2 10.8 20
Warning (Gas Models Only)
Dryers built for use with a voltage between 200
and 240 must verify the input voltage during
installation. If the nominal voltage is outside of the
medium tolerances shown on the diagram below, adjust
the autotransformer, located near the burner assembly. To
adjust the autotransformer wiring, place the red wire on the
appropriate tap (HIGH, MED, LOW) of the autotransformer.
For additional wiring details, refer to the electrical diagram
located on the inside of the control panel.
Electrical Service Specifications
Gas and Steam Models Only
!
TERM
LINE VOLTAGE
50 Hz 60 Hz
HIGH
260
226
283
249
MED
239
208
260
230
LOW
217
189
236
208