Maytag MDE17MN Clothes Dryer User Manual


 
4
Recessed front view Closet side view
Minimum Installation Clearances
Additional clearances for wall, door, and floor moldings may be required or if
external exhaust elbow is used.
closet
door
Front
View
7.6 cm (3")
7.6 cm (3")
155 cm
2
(24 in
2
.)*
310 cm
2
(48 in
2
.)*
*Opening is the minimum for a
closet door.
Louvered doors with equivalent air
openings are acceptable.
0 cm (0")
Closet
door
35.6 cm
(14") max.
2.5 cm (1")
0 cm (0")
38.1 cm
(15")*
0 cm
(0")
Product Dimensions 68.6 cm (27") dryer
6
8.6 cm (27")
9
4 cm
(37")
3
5.6 cm
(
14")
E
LECTRIC
EXHAUST
12.1 cm
(4
3
4")
3
3 cm
(
13")
BACK VIEW
10.2 cm (4")
dia.
2.5 cm
(1")
2
0 cm (7
7
8"
)
SIDE VIEW
88.9 cm
(35")
67.3 cm (26
1
/2")
74.3 cm (29
1
/4")
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector.
NOTE: The dryer must not be installed in an area where it will be
exposed to water and/or weather.
Recessed Area and Closet Installation Instructions
This dryer may be installed in a recessed area or closet.
This dryer must not be installed behind a lockable door,
a sliding door, or a door with a hinge on the opposite side
to that on the dryer.
The installation spacing is in cm and is the minimum allowable.
Additional spacing should be considered for ease of installation,
servicing, and compliance with local codes and ordinances.
If closet door is installed, the minimum unobstructed air opening
in the top and bottom is required. Louvered doors
with equivalent air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.