INSTALLATION INSTRUCTIONS
CONNECTING GAS DRYERS
GASREQUIREMENTS(GASMODELSONLY)
WARNING:
•Gassupplyrequirements:Asshippedfromthe
factory,thisdryerisconguredforusewithnatural
gas(NG).Itcanbeconvertedforusewithpropane
(LP)gas.Gaspressuremustnotexceed8inches
watercolumnfor(NG),or13incheswatercolumnfor
(LP).
•Aqualiedserviceorgascompanytechnicianmust
connect the dryer to the gas service.
•Isolate the dryer from the gas supply system by
closingitsindividualmanualshutovalveduringany
pressure testing of the gas supply.
•Supplylinerequirements:Yourlaundryroommust
have a rigid gas supply line to your dryer. In the
UnitedStates,anindividualmanualshutovalve
MUSTbeinstalledwithinatleast6ft.(1.8m)ofthe
dryer, in accordance with the National Fuel Gas Code
ANSI Z223.1 or Canadian gas installation code CSA
B149.1.A⅛inchNPTpipeplugmustbeinstalled.
•If using a rigid pipe, the rigid pipe should be ½ inch
IPS. If acceptable under local codes and ordinances
andwhenacceptabletoyourgassupplier,⅜inch
approved tubing may be used where lengths are less
than20ft.(6.1m).Largertubingshouldbeusedfor
lengthsinexcessof20ft.(6.1m).
ELECTRICAL REQUIREMENTS FOR
GAS MODELS ONLY
•Do not, under any circumstances, cut or remove the
third(ground)prongfromthepowercord. Failure
•For personal safety, this dryer must be properly
grounded.
•Thepowercordofthisdryerisequippedwith
a3-prong(grounding)plugwhichmateswitha
standard3-prong(grounding)walloutlettominimize
the possibility of electric shock hazard from this
appliance.
•This dryer must be plugged into a 120-VAC, 60-Hz.
grounded outlet protected by a 15-ampere fuse or
circuit breaker.
•Where a standard 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded 3-prong
wall outlet.
•Connect the dryer to the type of gas shown on
the nameplate.
•To prevent contamination of the gas valve, purge the
gas supply of air and sediment before connecting
the gas supply to the dryer. Before tightening the
connection between the gas supply and the dryer,
purge remaining air until the odor of gas is detected.
•DONOTuseanopenametoinspectforgasleaks.
Useanoncorrosiveleakdetectionuid.Failure to do
•UseonlyanewAGA-orCSA-certiedgassupply
linewithexiblestainlesssteelconnectors. Failure to
•Securely tighten all gas connections. Failure to do so
•UseTeontapeorapipe-jointcompoundthatis
insolubleinpropane(LP)gasonallpipethreads.
•DO NOT attempt any disassembly of the dryer;
disassemblyrequirestheattentionandtoolsof
anauthorizedandqualiedservicetechnicianor
company.
grounding
plug
grounding
type wall