Kenmore 26-88754 Washer/Dryer User Manual


 
Because of our continuous program of product improvement, Sears reserves the right to change models and specifications without notice. Consult installation instructions packed with the product for final dimensional data.
410/LCR/00
White on White – 26-88752
Almond on Almond – 26-88754
White on White – 26-98752
24" TRIMFIT
LAUNDRY CENTER
IMPORTANT NOTE ON DRYER VENTING
Do not use non-metal flexible duct. When installing the venting system, do not exceed the specified length for the vent
duct. Venting systems which are longer than specified will accumulate lint, increase drying time and energy use and
shorten the life of the dryer.
MINIMUM SPACING IN INCHES
RECESSED
INSTALLATION A B C D F G H
INSIDE
VENT 4041
OUTSIDE
VENT 1001
CLOSET
INSTALLATION A B C D F G H
OUTSIDE 60 60
VENT 1001
SQ. IN
.
1
SQ. IN.
When the Laundry Center is installed in other than the
recessed and closet type of installation shown, minimum
dimensions indicated must be observed.
To prevent large amounts of lint and moisture from
accumulating and to maintain drying efficiency, this
appliance must be vented outdoors.
G DBC
A
H
F
Closet
Door
SIDE VIEW FRONT VIEW
Dryer
Washer
Dryer
Washer
CLOSET INSTALLATION
VENTING INFORMATION
VENT HOOD TYPE
NUMBER
OF 90°
TURNS
0 36 ft. 34 ft. 29 ft. MAXIMUM LENGTH
1 26 ft. 24 ft. 20 ft. OF 4" DIAMETER RIGID
2 16 ft. 14 ft. 12 ft. HEAVY METAL VENT
0 22 ft. 21 ft. 16 ft. MAXIMUM LENGTH
1 16 ft. 15 ft. 10 ft. OF 4" DIAMETER FLEXIBLE
2 8 ft. 7 ft. 2 ft. METAL VENT
4"
4"
2
1
/
2"
26-2643, 26-2663
26-2644, 26-2664
OPTIONAL POWER CORDS
All Electric Dryers Require Cord
Electric Dryer Cords
Order Wire Length
26-2643 3 4 ft.
26-2663 3 6 ft.
26-2644* 4 4 ft.
26-2664* 4 6 ft.
*Complies with 1/1/96 NEC
code revision for new
construction and remodeling
DRYER VENTING RECOMMENDATIONS
4-WAY VENTING KIT
Available Through
Sears Parts & Service
1-800-225-2864
26-279818 – White, 26-279819 – Almond,
26-279820 – Black
26-98379 — VENT HOOD
Aluminum body and plastic molded hood
with a 4" opening.
4" Clearance Behind the Dryer is Preferred for Best Airflow.
2" Clearance is Achieved With Periscopes.
Recommended wall vent hole location: top of hole 36" from floor, centered behind dryer.
26-49900 — Over-The-Top
Kit
Universal solution, 8 foot length
4" Clearance Behind Dryer
26-49608 — Flexible Pipe
4" x 6' with snap-lock fittings
90˚ turn takes 1 foot length and
6" clearance
26-49609 — Close Elbow
Turns 90˚ within 4"
Rotating collars and snap-lock fittings
26-49908 — Periscope 0-18"
For outlets which overlap or are very close
26-49904 — Periscope 18-29"
Reaches side of most dryers
26-49905 — Periscope 29-50"
Reaches top of most dryers
Use 26-49608 Flexible Pipe
Clamps are recommended for wall and
dryer connections. Steel clamps designed
to resist stretching, with phillips/hex head
screw are included one each on elbows
and periscopes.
2" Clearance Behind Dryer
Laundry Centers
Gas Dryer Connector – Stainless Steel
26-49589
1
/
2
" -
3
/
8
" Flex, 5 ft.
26-49584*
3
/
8
" -
3
/
8
" Flex, 5 ft.
*Los Angeles only