Kenmore 240-Volt Compact Electric Dryer Clothes Dryer User Manual


 
Power Supply Cord Direct Wire
Fire Hazard
Use 10 gauge somidcopper wire.
Use a UL misted strain relief.
Disconnect power before making emectricamconnections.
Connect neutram wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 suppmy wires to remaining
2 termina_s (gored).
SecureBy tighten amlemectrical connections.
Failure to do so can resuJt in death, fire, or
electrical shock.
3. Assemble a 3/,,,(1.9 cm) UL listed strain relief (UL marking on
strain relief) into the hole below the terminal block opening.
Tighten strain relief screws just enough to hold the two clamp
sections together. Put power supply cord through the strain
relief. The strain relief should have a tight fit with the dryer
cabinet and be in a horizontal position.
A. Terminal block cover
B. External ground conductor screw
C. Center, silver-colored terminal block screw
D. Hold-down screw location
E. Neutral grounding wire (green with yellow stripes)
4.
Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)