Kenmore 22-46262 Washer User Manual


 
22-46262.PDF
Because of our continuous program of product improvement, Sears
reserves the right to change materials and specifications without
notice. Consult installation instructions packed with the product for
final dimensional data. For complete warranty information, contact
your local Sears Contract Sales Account Manager.
Effective 05/31/06
Rev. 1
07806
22-46262
30-Inch Manual-Clean Electric Coil Slide-Ins
page 2 of 2
All ranges are equipped with an
Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
RANGE CORD REQUIRED
Order Wire Length
22-49614 3 4 ft.
22-49616 3 6 ft.
22-49624* 4 4 ft.
22-49626* 4 6 ft.
22-49614,
22-49616
22-49624,
22-49626
*Complies with 1/1/96 NEC code revision for new construction and remodeling
21
3
/4" min.
22
1
/8" max.
CABINET
FRONT
1
1
/8"
22
7
/8" min.
††
23
1
/4" max.
Do not pinch the power supply cord between the range and the wall.
Do not seal the range to the side cabinets.
*Note: 24" min. clearance between the cooktop and the bottom of the cabinet when the
bottom of the wood or metal cabinet is protected by not less than 1/4" flame retardant
millboard covered with not less than No. 28 MSG sheet metal, 0.015" stainless steel,
0.024" aluminum, or 0.020" copper. 30" min. clearance when the cabinet is unprotected.
**Note: Minimum cutout depth is increased to 24" with optional backguard.
†Note: To avoid cooktop glass breakage for cutout width of more than 30 1/16",
make sure appliance is centered in the counter opening while pushing
into it. Raise leveling legs at maximum position, insert the appliance in the
counter and then level. Make sure the unit is supported by the leveling
legs and not by the smoothtop glass itself.
††For cutouts below 22 7/8”, appliance will slightly show out of the cabinet.
+Allow at least 19 1/4" clearance for door depth when it is open.
Shave Raised
Edge To Clear
31
1
/
2
" Wide
Cooktop.
1
1
/2" Max.
13"
30" Min.
For existing 29" cutout width
opening, you must call the Sears Service
Center for optional thinner side panels.
Also you must prepare the countertop
edge as shown in “Counterdepth
Preparation”.
Locate Cabinet
Doors 1" Min. From
Cutout Opening
18" Min.
Approx. 1
7
/8"
30" Min.*
30"
±
1
/16"
36
5
/8" Max.
35
5
/8" Min.
24" Min.
21
3
/4"
min.**
22
1
/8"
max.
Grounded Junction Box or Wall Outlet Should Be
Located 8" to 17" (20.3 - 43.2 cm) From Right of Cabinet
and 2" to 4" From Floor
28
5
/16"
Side Panel
Door Open+
21
3
/4"
35
5
/8" -
36
3
/8"
30"
31
1
/2"
Min.
cutout
width
3
/4"
3
/4"
31
1
/2"
COUNTERTOP PREPARATION
The cooktop sides of the range fit over the cutout edge of your countertop.
Countertop must be level.
If you have a square finish (flat) countertop, no countertop preparation is required.
Cooktop sides lay directly on edge of countertop.
Formed front-edged countertops must have molded edge shaved flat 3/4" from each
front corner of opening.
Tile countertops may need trim cut back 3/4" from each front corner and/or rounded
edge flattened.
If the existing cutout width is greater than 30 1/16", reduce the 3/4" dimension.
Formed or tiled
countertop
trimmed 3/4" back
at front corners of
countertop opening.