Kenmore 131801800 Washer User Manual


 
_For your safety the information in
this manual must be followed to minimize the risk of
fire or explosion orto prevent property damage,
personal injury or loss of life.
- Do not store or use gasoline or other flammable
vapors and liquid in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not tryto lightany appliance.
Do not touch any electrical switch; do not use
any phone inyour building.
Clear the room, buildingor area of all occupants.
Immediately call your gas supplier from a
neighbor's phone. Followthe gas suppliers
instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
PRE-INSTALLATION REQUIREMENTS
Tools Required for Installation:
1. l/4in, nutdriver
2. 318 in. socket with ratchet. |_
3, 3/8 in. open end wrench.
4. 7/16 in. socket with ratchet.
5. 9/16 in, open end wrench.
6. Channel-lock adjustable pliers.
7. Carpenter's level.
ELECTRICAL REQUIREMENTS
CIRCUIT - Individual, properly polarized and grounded
15 amp. branch circuitfused with 15 amp. time delay
fuse or circuit breaker•
POWER SUPPLY - 2 wire, with ground, 120 volt, single
phase, 60 Hz, Alternating Current.
OUTLET RECEPTACLE - Propedy grounded 3-preng
receptacle to be located so the power supply cord is
accessible when the washer is in an installed position.
GROUNDING REQUIREMENTS
[] Impropar connection ofthe equipment grounding
conductor can result in a risk of electrical shock. Check
with a licensed electrician if you are in doubt as to
whether the appliance is properlygrounded.
.
The washer MUST be grounded. In the event of
malfunction or breakdown, grounding will reduce
the risk of electrical shock by a path of least
resistance for electrical current.
.
Since your washer is equipped with a power supply
cord having an equipment-grounding conductor and
a grounding plug, the plug MUST be plugged into
an appropriate, copper wired receptacle that is
properly installed and grounded in accordance with
all local codes and ordinances or in the absence of
local codes, with the National Electrical Codes,
ANSI/NFPA 70 (latest edition). If in doubt, call a
licensed electrician. DONOT cut off or alter the
grounding prong on the power supply cord. In
situations where a two-slot receptacle is present, it
is the owner's responsibility to have a licensed
electrician replace it with a properly grounded
three prong grounding type receptacle.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within
42 inches (107 cm) of your washer's water inlet.The
faucets MUST be 3/4 inch (1.9 cm) garden hose type
so inlet hoses can be connected. Water pressure MUST
be between 10 and 120 pounds per square inch
(maximum unbalance pressure, hot vs. cold, 10 psi.)
Your water department can advise you of yourwater
pressure. The hot water temperature shouldbe about
120 degrees F (49 degrees C).
DRAIN REQUIREMENTS
1. Drain capable of eliminating 17 gals (64.3 L) per
minute.
2. A standpipe diameter of 1-1/4 in. (3.18 cm)
minimum.
3. The standpipe height above the floor should be:
Minimum height: 24 in. (61 cm)
Maximum height: 96 in. (244 cm)
II
_j
_ _ BACK =___
96 in.
(244 cm)
Max.
NOTE:
Drain hose attached to the washer can reach a 58
in. (147 cm) high standpipe• For higher standpipe
use hose P/N 131461201, available from Sears
Parts and Service. If drain is less than 24 in. (61
cm), install a siphon break kit, DIV 26110285320,
available from Sears Parts and Service.
2