START/PAUSE button
After the power is switched on,press it to
start the machine
During working,pushit to pause.
During pause,push this button to restart
and go on working
Connection between the water inlet hose and the washer
1.Do not take off the water absorption cushion. Please check if the
cushion is dropped or damaged before each usage. If it happens
please contact our after-sale department immediately.
2 Put the nut of the water inlet hose on the valve jointer.
3 Fasten the nut. Swing it gently to confirm if it's suitable.
nut of the water
inlet hose
jointer of the
water inlet valve
water absorption
cushion.
Connection between the jointer of the water inlet hose and the water inlet hose
1.Push down the slider. Insert the water inlet hose into the jointer.
2 Hang the lock lever to the jointer. Release the slider till a click
sound is heard.
Locking level
the jointer of the
water inlet hose
Slider
Check the connection between the jointer of the water inlet hose
and the water faucet
1.Swing the hose gently to confirm if it is fastened stable.
2.After installation, open the faucet to check if it leaks.
3.Do not bend the hose with overstrain.
4.Before each usage please check if the connection
between the jointer of the water inlet hose and the
water faucet, and the installation of the water inlet
hose are firm, so as to prevent dropping from
improper installation position.
Dismantle the water inlet hose
1. Close the water faucet.
2. Press the locking lever. Push down the slider. Then pull of the water inlet
hose.
If the machine is used frequently, the jointer of the water inlet hose can be
kept
on the faucet to prevent damaging the fixing screw.
Locking level
Slider
a
5 Use the operation button
Description of operation button
Indicator mode and meaning
Flashing, indicating the running program
On, indicating the program about to run or the selection mode
nano wash
START
PAUSE
SOAK WASH
SAVE
SINGLE WASH
SINGLE SPIN
TUB CLEAN
GENTLE
COTTON
RINSE SPIN
GENTLE SPIN
SOAK
WASH
SPIN
RINSE
Program
Process
STANDARD
TIME REMAINED
RESERVE