8).Dispenser
9)Condenser
10) Hose connecting condenser to hose of outer cylinder
2.Fasting the U-bolt.
3.Wipe off the foreign object from the cushion of sight window.
IX .Improper distribution of dispenser
Possible causes
1.The plug wire of the water eletromagnetic valve is mistaked.
2.The PCB is broken.
3.Fault of assemblage of dispenser.
Troubleshooting
1.Reassemble the plug wire.
2.Replace the PCB with a new one.
3.Reassemble the assemblage of dispenser.
X.The door lock indicator does not light
XI.No function or malfunction of program controller
Possible causes
1.The door lock indicator is broken.
2.The wiring of micro delay switch is loose.
3.The indicator loses.
Troubleshooting
1.Replace the broken indicator.
2.Tighten the stub of micro delay switch.
3.Refasten the indicator.
Possible causes
1.The motor of program controller loses or the stub is sealing-off.
2.The knob of program controller is stuck.
3.Poor contact of wiring of program controller.
4.Poor contact at inner contacts of program controller (even after the all the plug wires are
tightened.)
Troubleshooting
1.Reassemble the motor of program controller and make spot welding of the stubs (the
operation of program controller and motor can be heard after the appliance is turned on.)
2.Adjust the position of knob of program controller.
3.Tighten the stubs of program controller one by one.
4.Replace the program controller with a new one.