Do Not Install Your Dryer:
• In an area exposed to dripping water or outside weather conditions.
• In an area where it will come in contact with curtains, drapes, or
anything that will obstruct the flow of combustion and ventilation air.
• On carpet. Floor must be solid with a maximum slope of
1inch (2.54 cm).
Installation in Recess or Closet:
• A dryer installed in a bedroom, bathroom, recess or closet, must be
exhausted outdoors.
• Your dryer needs the space around it for proper ventilation.
• A minimum of 120 square inches (774.2 square cm) of opening,
equally divided at the top and bottom of the door, is required. Air
openings are required to be unobstructed when a door is installed. A
louvered door with equivalent air openings for the full length of the
door is acceptable.
Location of Your Dryer
ROUGH-IN DIMENSIONS