4
INSTALLATION INSTRUCTIONS
Phillips head and flathead screwdrivers
Channel-lock adjustable pliers
1/2 inch open end wrench
Carpenter s level
Measuring tape (12ft. Min.)
Duct tape
Rigid or flexible metal 4 inch (10.2 cm) duct
Vent hood
1. Remove all packaging material. This includes the foam base and all adhesive
tape holding the dryer accessories inside and outside.
2. Inspect and remove any remains of packaging, tape or printed
materials before using the dryer.
Tools and Materials Required
Electrical Requirements
Unpacking Your Dryer
English
Select a suitable location for the dryer on a hard even surface away from
direct sunlight or heat sources, baseboard heaters, cooking appliances etc.
Any floor unevenness should be corrected with leveling legs located on the
bottom of the dryer.
U.S. Only
Power supply:
3 or 4 wire, 240 Volt, 30 Amp,60Hz, 1 Phase Power Supply Cord Kit (not
supplied when sold in the United States) – Purchase to meet local electrical codes.
The dryer MUST employ a 3-conductor power supply cord NEMA 10-30 Type
SPDT RATED AT 240 Volt AC minimum, 30 Amp., with 3 open end spade lug
connectors with upturned ends or closed loop connectors and marked for use with
clothes dryers. If being installed in a manufactured (mobile) home,the dryer MUST
employ a 4-conductor power supply cord. NEMA 14-30 type SRDT or ST (as
required) rated at 240 Volt AC Minimum, 30 Amp., with 4 open end spade lug
connectors with upturned ends or closed loop connectors and marked for use with
clothes dryers. See Electrical Connections for A 4-Wire System.
Canada. Only
Candian models are supplied with the appropriate power cord.