10. Electrical Load Information
1218
1 PH 230V
Top Auger 5 26
286 178 400
100
Bottom Auger 5 26 100
Top Fan 10 to 17 78 100
Bottom Fan 10 to 12 48 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 5 13.2
183 98.4 225
60
Bottom Auger 5 13.2 60
Top Fan 15 39 60
Bottom Fan 10 to 12 33 60
(2) Auxiliary (2) 10 52 *
3 PH 440V
Top Auger 5 6.6
96 49.2 150
60
Bottom Auger 5 6.6 60
Top Fan 15 19.5 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 10 26 *
1220
1 PH 230V
Top Auger 7.5 31
298 188 400
100
Bottom Auger 7.5 31 100
Top Fan 10 to 17 78 100
Bottom Fan 10 to 12 48 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 7.5 20
229 112 300
90
Bottom Auger 7.5 20 90
Top Fan 15 39 60
Bottom Fan 10 to12 33 60
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 7.5 10
123 59 200
60
Bottom Auger 7.5 10 60
Top Fan 15 19.5 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 15 39 *
1222
3 PH 220V
Top Auger 7.5 20
241 123 350
90
Bottom Auger 7.5 20 90
Top Fan 20 50 90
Bottom Fan 10 to 12 33 60
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 7.5 10
129 64.5 200
60
Bottom Auger 7.5 10 60
Top Fan 20 25 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 15 39 *
1226
3 PH 220V
Top Auger 10 26
271 149 350
90
Bottom Auger 10 26 90
Top Fan 25 64 90
Bottom Fan 10 to 12 33 60
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 10 13
144 77.5 200
60
Bottom Auger 10 13 60
Top Fan 25 32 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 15 39 *
*Auxiliaries run through load and unload breakers.
Dryer
Model #
Voltage Motor HP
Fuel Load
Amps
Maximum Amps
with Auxiliaries
Minimum
Amps
Recommended
Service in Amps
Branch Breaker