GE WWA8810R Washer User Manual


 
PROBLEM
THE PROBLEM SOLVER
(continued)
WASHER IS NOISY
A sharp, distinctive sound will be heard at the end of each spin period as the motor
stops and the spin brake inside the transmission “locks in.” This sound is normal.
WASHER PAUSES
IN CYCLE
POSSIBLE CAUSE
Make sure washer is level and firm to the floor with rubber foot pads in place and
front jam nuts tight. See your Installation Instructions.
Heavily unbalanced loads can cause the washer to vibrate excessively during spin,
and may cause it to move from its original position. In extreme cases (usually occurs
when washing a single, heavy item or a small load when water level is set higher than
necessary), the spin basket may strike the outer tub, creating a loud but harmless noise.
To correct, open the lid and redistribute the load evenly about the wash basket. Close
the lid and restart.
Washer normally pauses between washing steps.
..such
as between wash and spin or
between spin and rinse.
If you need more help...call, toll free: GE Answer Center
@
/ 800.626.2000/ consumer information service
CARE
AND CLEANING
USER MAINTENANCE INSTRUCTIONS
The
~b.
To Store Washer.
The porcelain is self-cleaning. Leave
lid
open after
Ask service technician to remove water
washing to
allow
moisture to evaporate. Do not use
from drain pump and hoses to prevent freezing.
harsh or gritty cleansers.
Do
not store the washer where it will be exposed
The Exterior.
to the weather.
Wipe off any spills of washing compounds. Wipe
For Long Vacations.
or dust with damp
cloth.
Try not to hit surface with
Be sure water supply is shut off at faucets
sharp objects.
and drain all water from hoses if weather will
The
Power-Flo’M
Lint Filter.
be below freezing.
Your lint filter is located under the agitator. It is
maintenance-free.
How to remove the agitator
To remove limestone from
Filter-Flo
pan
To remoye the agitator,
snap the cap off and remove
the screw. Then remove
the agitator extender (on
models so equipped)
and the agitator.
To replace the agitator,
carefully lower it straight
down onto the shaft so
that it fits snugly into
place. Replace the agitator
extender (on
models
so
equipped), the screw
and the cap.
Cap
Soak filter pan in a preheated
160°F.
(71 ‘C.)
6
Screw
solution of half vinegar and half water for 15
:,
Agitator
minutes. Then brush each side of pan with a stiff
Extender
bristle brush
while flushing with running water.
&
(on some models)
.
A
— Agitator
,
,’,
CAUTIONS:
Do not soak in porcelain container. Vinegar
can damage porcelain.
. .
.
8
Do not exceed
180°F.
(82°C.
) or
filter
pan
Shati
may warp.
(Appearance may vary)
26