GE WSM2780HWW Washer/Dryer User Manual


 
Dimensions and Installation Information (in inches)
360326
WSM2700/80H
GE
®
27" Unitized Spacemaker
®
Washer and Dryer
Listed by
Underwriters
Laboratories
Specification Revised 5/09
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal duct
cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In special installa-
tions, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed
flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid) duct-
ing cannot be used AND where a 4” diameter can be maintained throughout the entire length of the transition
duct. Please see installation instruction packed with your dryer for complete instructions when using flexible metal
(foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer,
add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn
over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl
space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage.
Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap
must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
Special Installation Requirements
Alcove or Closet Installation:
If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side and rear
1" front and top
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area
equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in.
of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Electric
Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" either side and rear
1" front and top
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at ge.com
or call GE Answer Center
®
service, 800.626.2000.
Best performance
Domestic
dryer models
Maximum length of 4"
dia. rigid metal duct
Number
of
90°
turns
Exhaust hood type
A
4"
opening
B
2-1/2"
opening
DSKS433EB
DSKS333EC
DSKP333EC
WSM2780H
0
1
2
3
46 ft.
38 ft.
31 ft.
24 ft.
37 ft.
30 ft.
22 ft.
15 ft.
WSM2700H
0
1
2
3
56 ft.
46 ft.
34 ft.
32 ft.
42 ft.
36 ft.
28 ft.
18 ft.
WSM2420D
WSM2480D
0
1
2
43 ft.
33 ft.
23 ft.
36 ft.
26 ft.
16 ft.
A
4
B
2-1/ 2