Care and Maintenance
Hoefer SE 1200 Easy Breeze Air Gel Dryer
11
Care and Maintenance
Cleaning
N
OTE
Never autoclave or heat any component above 55 °C.
After each use, wipe the dryer with a damp cloth. Clean each frame with mild soap and
water, rinse thoroughly with water and distilled water, and allow to air dry. Never use
abrasive cleansers on any part. Do not expose the frame to solutions or vapors of
aromatic or halogenated hydrocarbons, ketones, esters, alcohols (over 30%), or
concentrated acids (over 25%).
Changing the gasket
If the gasket on the inner frame becomes inflexible or no longer holds the gel stack
tautly, remove it and install a new gasket, stretching it slightly around three sides and
then rolling it into place on the fourth.
Changing fuses
N
OTE
Fuses protect equipment by disconnecting loads too large for the
instrument's circuit design. Replace fuses only with identical fuse
values.
115 V~ model: one F 12A 250V 3AG
230 V~ model: two T 6.3A 250V, 5 x 20 mm
1. Caution! Set the power switch to off and unplug the power cord before replacing
the fuse.
2. Insert a small flat-blade screwdriver into the slot on the fuse module, depress
slightly, and turn it ¼-turn counterclockwise. The spring-loaded module cap will
loosen and you can then pull the cap/fuse holder out.
3. Pull the fuse out of its holder and inspect. If the fuse element is burned or broken,
replace the fuse with an identical type. If the fuse appears to be intact, check it with
a multi-meter. (A reading of 1 or less indicates the fuse is still usable.)
4. Insert the fuse into the holder and then insert this assembly back into the unit. Seat
the module by inserting the screwdriver into the slot, pressing gently, and turning
the cap ¼-turn clockwise.
5. 230 V~ model: Repeat steps 2 to 4 for the second fuse.