9
NON-CANADIAN ELECTRIC Laundry Center
5. Attach the remaining two power cord outer conductors to
the outer brass colored terminals on the terminal block.
Tighten both screws securely.
6. Tighten the screws securing the cord restraint against the
power cord.
7. Reinstall the terminal access cover.
SILVER TERMINAL
GREEN GROUND SCREW
NEUTRAL
GROUND
WIRE
ELECTRICAL CONNECTIONS
FOR A 3-WIRE SYSTEM
1. Remove the screw securing the
terminal block access cover to
the rear panel and remove cover.
2. Install a U.L. approved strain
relief connector in the entry
hole on the back panel.
3. Insert a NEMA 10-30 Type SRDT,
U.L. approved power cord through the strain relief.
4. Attach the power cord neutral (central wire) conductor to
the silver colored center terminal on the terminal block.
Tighten the screw securely.
NON-CANADIAN ELECTRIC
Laundry Center
NEUTRAL
GROUND
WIRE
1. Remove the screw securing the
terminal block access cover to the
rear panel and remove cover.
2. Install a U.L. approved strain relief
connector in the entry hole on the
back panel.
3. Remove the neutral ground wire from the green ground
screw located above the termial block.
4. Insert a NEMA 14-30 Type ST or SRDT, U.L. approved power
cord through the strain relief.
5. Attach the green power cord ground wire to the cabinet
with the green ground screw.
6. Attach the white (neutral) wire from the power cord and the
neutral ground wire from the appliance harness to the silver
colored center terminal on the terminal block. Tighten the
screw securely.
7. Attach the red and black wires from the power cord to the
outer brass-colored terminals on the terminal block. Tighten
both screws securely.
8. Tighten the screws securing the cord restraint firmly against
the power cord.
9. Reinstall the terminal block access cover.
ELECTRICAL CONNECTIONS
FOR A 4-WIRE SYSTEM