Fisher & Paykel DEGX1US Clothes Dryer User Manual


 
3-wire connections
For use where local codes permit grounding through the Neutral wire.
Use approved 3-wire Power Supply Cord or a 3-wire Cable for Direct Wiring as described on page 18.
1. Remove the terminal block cover plate.
2. Insert the power cord with a UL listed strain relief through the hole provided in the cabinet near
the terminal block. Do not tighten strain relief screw until wiring connections are complete.
Note: a strain relief must be used.
strain relief
screw
s
strain relief
clamp sections
2
3. Loosen or remove the center terminal block screw. Connect the neutral wire (center) of the
power supply cord to the center terminal screw of the terminal block. Tighten screw.
4. Connect the other wires to the upper and lower terminal block screws marked with the
letter L. Tighten screws.
3
4
4
Note: If the appliance is
moved back to a 3-wire
installation the ground
link must be refitted.
5. Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer. Secure
cover with securing screw.
6. Tighten strain relief screws.
5
6
20 21