Fisher & Paykel DE62T27C Clothes Dryer User Manual


 
9
Installation instructions
Location requirements
The area in which the dryer is located must be
kept clear and free from combustible materials,
gasoline and other flammable vapors and
liquids. A dryer produces combustible lint so the
area around the dryer must be cleaned regularly
to keep it free of lint.
This dryer can only be vented from the rear and must be exhausted to the outdoors.
Alcove or closet installation
WARNING!
When installing a dryer in a closet/alcove it must be exhausted to the outdoors. No other
fuel burning appliance can be installed in the same closet or alcove.
The top opening area in the door must be a minimum of 48 square inches (3100 mm
2
) and the
bottom opening area must have a minimum of 24 square inches (1550 mm
2
). These openings
must never be obstructed (a louvred door with the minimum air opening is acceptable).
Minimum installation clearances are required but more clearance is recommended.
1” (25 mm) 1” (25 mm) 1” (25 mm)
min 2” (50 mm) min 3” (76 mm)
min 56 /”
(1430 mm)
Fig.4 Minimum clearances
48 sq” (3100 mm
2
)
total ventation area
72 sq” (4650 mm
2
)
24 sq” (1550 mm
2
)
Fig.5 Minimum ventilation
Fig.3 Rear venting
EN