Electrolux LAVATHERM 58840 Clothes Dryer User Manual


 
The appliance is supplied with a 13 amp plug fitted. In the event of having to change
the fuse in the plug supplied, a 13 amp ASTA approved BS 1363/A fuse must be
used.
The wires in the mains lead are coloured in
accordance with the following code:
1 Blue - Neutral
2 cord clamp
3 Brown - Live
4 Green and Yellow - Earth
The wire coloured green and yellow must be
connected to the terminal marked with the
letter «E» or by the earth symbol
or col-
oured green and yellow.
The wire coloured blue must be connected to
the terminal «N» or coloured black.
The wire coloured brown must be connected to the terminal marked «L» or coloured
red.
Upon completion there must be no cut, or stray strands of wire present and the
cord clamp must be secure over the outer sheath.
WARNING!
A cut off plug inserted into a 13 amp socket is a serious safety (shock)
hazard.
Ensure that the cut off plug is disposed of safely.
WARNING!
The power supply cable must be accessible after installing the machine.
Permanent connection
In the case of permanent connection it is necessary that you install a double pole
switch between the appliance and the electricity supply (mains), with a minimum
gap of 3 mm between the switch contacts and of a type suitable for the required
load in compliance with the current electrical regulations.
The switch must not break the yellow and green earth cable at any point.