What to do if ...
25
If after these checks, the tumble dryer still does not work, contact your
local AEG Service Force Centre.
Please note that it will be necessary to provide proof of purchase for
any in-guarantee service calls.
In-guarantee customers should ensure that the above checks have been
made as the engineer will make a charge if the fault is not a mechani-
cal or electrical breakdown.
Replacing the interior light
0 A replacement bulb can be purchased through your local AEG Service
Force Centre (Part No: 899647072580/6).
1
Warning! Never use standard light bulbs in your Lavatherm.
0 Isolate the appliance from the mains supply.
0 Screw-off the bulb cover. (The bulb is located at the top behind the
door; see Front view).
0 Replace the defective bulb.
0 Screw-on the bulb cover.
1
Warning! For safety reasons the bulb cover must be screwed-on. The
dryer must not be operated, without the cover in place.
The door cannot be closed
Fluff filter has not been
inserted correctly and/or
the filter lid not closed
Replace the fluff filter
and ensure the filter lid is
closed
The dryer terminates the
drying process automatically:
END is displayed shortly after
programme start
Too dry or too little
laundry is in the drum for
the selected programme
Select time programme or
higher drying stage (e.g.
EXTRA DRY instead of
INTENSIVE DRY)
The drying process takes
unusually long. 4.5 hours
after the beginning of the
drying process:
- END display is illuminated
- acoustic signal sounds
- discontinuation of the
drying process
-
programme run display is
flashing
SPECIAL CARE button
pressed and too much
laundry in the drum
Check the programme
selection: SPECIAL CARE
button appropriate only
for laundry amounts up
to 2.5kg
Too much laundry in the
drum
Reduce the amount of
laundry in the drum
Laundry too damp
Pre-dry (spin) the laundry
more thoroughly
Symptom Possible cause Solution