c) Mounting the door
Fix the hinges (1) to the machine by means of the M5x8 screws (3-Fig. B).
The hinges can be adjusted to compensate for possible uneven thick-
ness of the door.
To align the door perfectly it is necessary to loosen the screw (3-Fig. B),
adjust the door and tighten the screw again.
d) Counter-magnet (6)
The appliance is pre-arranged for a magnetic
closure of the door. To enable a correct oper-
ation of this device, it is necessary to screw
the counter-magnet (6) (steel disk + rubber
ring) into the inner side of the door.
Its position must correspond to the magnet (4)
on the appliance (see picture D).
If the door has to be opened from
left to right, invert the position of
the plates (7), the magnet (4) and
the plate (5) (Fig. B and E). Mount
the countermagnet (6) and the
hinges (1) as previously described.
Important: the plastic screw (8)
should never be loosened (Fig. B
and E).
56
Building-in