ELECTRICAL
CONNECTIONS
FOR ALL DRYERS
Dryers must be electrically grounded by a separate #14 or larger
green wire from the grounding terminal within the service connection
box, to a cold water pipe. In all cases, the grounding method must
comply with local electrical code requirements; or in the absence of
local codes, with the National Electrical Code as ANSI/NFPA No.
70—Latest Edition.
See wiring diagram furnished with dryer. Your Cissell dryer is
completely wired at the factory and it is only necessary for the
electrician to connect the power leads to the wire connectors within
the service connection box on the rear of the dryer. Do not change
wiring without consulting the factory, as you may void the factory
warranty. DO NOT CONNECT THE DRYER TO ANY
VOLTAGE OR CURRENT OTHER THAN THAT SPECIFIED
ON THE DRYER RATING PLATE. (Wiring diagram is located on
rear wall of dryer.)
All panels must be in position before operation of dryer.