Cissell HF 234 Washer User Manual


 
17
4
B
A
Linking 2 programs
It is possible to run 2 programs automatically in sequence. This can be handy
to perform very special functions (like waterproofing outerwear) and add these
to the wash program.
Programming:
First select the program which will be run last.
Now, press the START-button (S) and keep it depressed for at least 5 seconds.
The left display now shows “Add”. Now select the program which will be run
first.
The right display now shows both linked programs alternately: the first to be
run program during the longer time span alternating with the following program
displayed during the shorter time span.
This function is canceled by pressing the START-button (S) again for at least
5 seconds.
This function can be combined with an economy wash, with the functions F1
to F6 and with a programmed start. The freely programmable stop-function can
however only be executed during the first program.
Operation:
Press the START-button (S) to start the programs. The central display will show
the remaining time per program. The total time of both programs together is not
displayed.
The right display alternately shows the program in operation (during a longer
time span) and the second program to be executed (during the shorter time span).
After the first program has been run, only the second program number will be
displayed.
Cool down
This function allows to gradually lower the temperature of the wash bath to
prevent creasing of the linen.
During a cool down, the remaining program time on the central display will be
replaced by “cd”.
Power Failure
Should the power fall out during the program, the water will be drained and the
door can be opened after maximum 3 minutes. When the door remains locked,
and the power comes back up within 24 hours, the program will continue from
there, where it was at the time of the power failure.
If due to breakdown, the door is not unlocked automatically, you have to remove
the service panel (A) below and pull the ring (B), suspended on the left side, while
opening the door.
Before opening the door, check that all the water has been drained from the
tub and that the cylinder has come to a complete stop.
Important:
Remote stop function
By means of this function, no cycles can be selected anymore during a certain
period of time (e.g. between 10 p.m. and 7 a.m.). This time is determined by an
extern timer. As soon as the last cycle is finished,
OFF “ (blinking) appears on the left display as long as this function is activated.