Ariston AQ9L 29 U Washer/Dryer User Manual


 
AUS
3
Connecting the drain hose
Connect the drain hose to
drain duct piping or a wall
drain located between 65
and 100 cm above the floor,
making sure it is not bent
at all.
Alternatively, rest the
drain hose on the side of
a washbasin or bathtub,
fastening the duct supplied
to the tap (see figure).
The free end of the hose
should not be underwater.
! We advise against the use of hose extensions; if it is
absolutely necessary, the extension must have the same
diameter as the original hose and must not exceed 150 cm
in length.
Electrical connections
Before inserting the plug into the electrical socket, make
sure that:
• the socket is earthed and complies with current
regulations;
• the socket can withstand the maximum load of the
appliance, which is indicated in the Technical data table
(see opposite);
• the power supply voltage falls within the values indicated
in the Technical data table (see opposite);
• the socket is compatible with the plug of the appliance.
If this is not the case, either the socket or the plug must
be replaced.
! The machine must not be installed outdoors, even in
covered areas. It is extremely dangerous to leave the
appliance exposed to rain, storms and other weather
conditions.
! Once the machine has been installed, the electricity
socket should be easily accessible.
! Avoid using any extension cord or multiple socket outlet.
! CAUTION: if this appliance is supplied from a cord
extension set or electrical portable outlet device, the cord
extension set or electrical portable outlet device
must be positioned so that it is not subject to splashing or
ingress of moisture.
! The cable should not be bent or compressed.
! The cable should be replaced only by authorised
technicians.
! If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
Warning! The company shall not be held responsible in the
event that these regulations are not respected.
65 - 100 cm
Technical data
Model
AQ9L 29 U
Dimensions
width 59.5 cm
height 85 cm
depth 64,5 cm
Capacity
from 1 to 8,5 kg
Electrical
connections
please refer to the technical data plate
fixed to the machine
Water connections
maximum pressure 1 MPa (10 bar)
minimum pressure 0.05 MPa (0.5 bar)
drum capacity 62 litres
Spin speed
up to 1200 rotations per minute
Energy rated
programmes
according to
AS/NZS 2040.2
Program Cotton
; temperature 60°C;
1200 rpm, using a load of 8,5 kg.
This appliance conforms to the following
EC Directives:
- 2004/108/EC (Electromagnetic Compa-
tibility)
- 2006/95/EC (Low Voltage)
- 2002/96/EC