American Dryer Corp. SL20 Clothes Dryer User Manual


 
113403-14 www.amdry.com 21
Gas Specifications for Non-CE and Non-AGA Approved Dryers**
Model
Gas
Type
Nominal
Heating Value
Supply
Pressure
Gross
Heat Input
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
in WC Btu/hr kW DMS mm in WC
SL20
Natural 1,000
7.0-13.0
40,000
11.72
30
3.264
1
3.0
*Liquid Propane 2,500
11.0
40,000
11.72
49
1.854
1
10.0
SL31
Natural 1,000
7.0-13.0
55,000
16.12
20
4.089
1
3.0
*Liquid Propane 2,500
11.0
55,000
16.12
44
2.184
1
10.0
SL50
Natural 1,000
7.0-13.0
90,000
26.38
29
3.454
2
3.0
*Liquid Propane 2,500
11.0
90,000
26.38
47
2.994
2
10.0
SL75
Natural 1,000
7.0-13.0
110,000
32.24
22
3.988
2
3.0
*Liquid Propane 2,500
11.0
110,000
32.24
44
2.184
2
10.0
Heat Input/Gas Consumption/Orifice (Injector) Data
(For Non-CE [European] and Non-AGA [Australia] Models Only)
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)
Gas Specifications for CE Approved Dryers**
Model
Gas
Type
Nominal
Heating Value
Supply
Pressure
Gross
Heat Input
Fuel
Consumption
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
mb Btu/hr kW DMS mm mb
SL20
Natural (I
2H
/I
2E
)1,000
15-30
40,000
11.72 1.133 M
3
/H
30
3.264
1
6.7
Natural (I
2L
) 830
20-35
40,000
11.72 1.365 M
3
/H
30
3.264
1
9.2
Natural (I
2ELL
) 830
15-30
40,000
11.72 1.365 M
3
/H
30
3.264
1
9.2
*Natural (I
2E+
)
1,000
20
40,000
11.72 1.133 M
3
/H
38
2.578
1
830
25
40,000
11.72 1.365 M
3
/H
38
2.578
1
*Butane (I
3+
) 3,175
28-30
40,000
11.72 0.845 kg/H
52
1.613
1
*Propane (I
3+
) 2,500
37
40,000
11.72 0.845 kg/H
52
1.613
1
Butane (I
3B/P
) 3,175
28-30/50
40,000
11.72 0.845 kg/H
49
1.854
1
18.0
Propane (I
3P
) 2,500
28-30/50
40,000
11.72 0.845 kg/H
49
1.854
1
23.0
SL31
Natural (I
2H
/I
2E
)1,000
15-30
55,000
16.12 1.557 M
3
/H
22
3.988
1
6.9
Natural (I
2L
) 830
20-35
55,000
16.12 1.876 M
3
/H
22
3.988
1
9.5
Natural (I
2ELL
) 830
15-30
55,000
16.12 1.876 M
3
/H
22
3.988
1
9.5
*Natural (I
2E+
)
1,000
20
55,000
16.12 1.557 M
3
/H
31
3.048
1
830
25
55,000
16.12 1.876 M
3
/H
31
3.048
1
*Butane (I
3+
) 3,175
28-30
55,000
16.12 1.162 kg/H
48
1.930
1
*Propane (I
3+
) 2,500
37
55,000
16.12 1.162 kg/H
48
1.930
1
Butane (I
3B/P
) 3,175
28-30/50
55,000
16.12 1.162 kg/H
44
2.184
1
18.1
Propane (I
3P
) 2,500
28-30/50
55,000
16.12 1.162 kg/H
44
2.184
1
24.9
SL50
Natural (I
2H
/I
2E
)1,000
15-30
90,000
26.38 2.549 M
3
/H
29
3.454
2
7.2
Natural (I
2L
) 830
20-35
90,000
26.38 3.071 M
3
/H
29
3.454
2
8.9
Natural (I
2ELL
) 830
15-30
90,000
26.38 3.071 M
3
/H
29
3.454
2
8.9
*Natural (I
2E+
)
1,000
20
90,000
26.38 2.549 M
3
/H
35
2.794
2
830
25
90,000
26.38 3.071 M
3
/H
35
2.794
2
*Butane (I
3+
) 3,175
28-30
90,000
26.38 1.901 kg/H
50
1.778
2
*Propane (I
3+
) 2,500
37
90,000
26.38 1.901 kg/H
50
1.778
2
Butane (I
3B/P
) 3,175
28-30/50
90,000
26.38 1.901 kg/H
47
1.994
2
18.1
Propane (I
3P
) 2,500
28-30/50
90,000
26.38 1.901 kg/H
47
1.994
2
24.9
SL75
Natural (I
2H
/I
2E
)1,000
15-30
110,000
32.24 3.115 M
3
/H
22
3.988
2
6.9
Natural (I
2L
) 830
20-35
110,000
32.24 3.753 M
3
/H
22
3.988
2
9.5
Natural (I
2ELL
) 830
15-30
110,000
32.24 3.753 M
3
/H
22
3.988
2
9.5
*Natural (I
2E+
)
1,000
20
110,000
32.24 3.115 M
3
/H
31
3.048
2
830
25
110,000
32.24 3.753 M
3
/H
31
3.048
2
*Butane (I
3+
) 3,175
28-30
110,000
32.24 2.324 kg/H
48
1.930
2
*Propane (I
3+
) 2,500
37
110,000
32.24 2.324 kg/H
48
1.930
2
Butane (I
3B/P
) 3,175
28-30/50
110,000
32.24 2.324 kg/H
44
2.184
2
18.1
Propane (I
3P
) 2,500
28-30/50
110,000
32.24 2.324 kg/H
44
2.184
2
24.9