American Dryer Corp. ML-78II Clothes Dryer User Manual


 
31
b. Dual Timer Models
1) Both dwell (stop) time and basket (tumbler) spin time are adjustable (refer to the illustration on
page 37).
8. Check to insure that ALL setscrews (i.e., basket [tumbler] drive, idler, etc.) are tight.
J. PREOPERATIONAL INSTRUCTIONS
1. To start the dryer...
a. Microprocessor Controller (Computer) Dryers...
1) The light emitting diode (L.E.D.) display will read “REAdY.”
2) Press the “E” on the keyboard (touch pad).
3) The dryer will start and the display will flash “dRYING MANUAL CYCLE E” “dRY TEMP 180º F
(82º C)” “COOL TEMP 80º F (27º C)” “30 REMAIN” “dRUM TEMP.”
Refer to the User’s Manual for detailed operating instructions.
b. Dual Timer Dryers...
1) Turn drying timer knob for a time of 20 minutes.
2) Select “High Temp.”
3) Push “Push To Start” switch.
4) To stop dryer, open the main door.
K. SHUT DOWN INSTRUCTIONS
If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply:
a. GAS MODELS...discontinue the gas supply.
1) SHUT OFF external gas supply shutoff valve.