F. ELECTRICAL INFORMATION
1. Electrical Requirements
It is your responsibility to have
ALL electrical connections made by a properly licensed and competent
electrician to assure that the electrical installation is adequate and conforms to local and state regulations or
codes. In the absence of such codes,
ALL electrical connections, materials, and workmanship must
conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST
EDITION, or in Canada, the installation must conform to applicable Canadian Standards: Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical Connections).
IMPORTANT: Failure to comply with these codes or ordinances and/or the requirements stipulated in
this manual can result in personal injury or component failure.
NOTE: Component failure due to improper installation will VOID THE WARRANTY.
IMPORTANT: Each circuit must be connected to an independently protected branch circuit.
IMPORTANT: USE ONLY COPPER CONDUCTOR CABLE of proper ampacity and insulation in
accordance with electrical codes for making service connections.
NOTE: The use of aluminum wire will VOID THE WARRANTY.
IMPORTANT: A separate circuit servicing each dryer must be provided.
2. Electrical Service Specifications
a. Electric Service
1) Gas Models
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the upper left side panel area behind the top control (access) door. In the
case of 208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
IMPORTANT: USE ONLY COPPER CONDUCTOR CABLE of proper ampacity and insulation in
accordance with electrical codes for making service connections.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: On gas dryers, to convert from 208 VAC to 240 VAC (or visa versa), the 24 VAC
transformer wiring sequence must be changed.