American Dryer Corp. MDG-30 Clothes Dryer User Manual


 
21
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the upper left side panel area behind the top control (access) door.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: Any damage done to dryer components due to improper voltage connections will
automatically VOID THE WARRANTY.
NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or
obligation.
GAS
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
NOTES: A. When fuses are used they must be dual element, time delay, current limiting,
class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying
either local and/or National Elctrical Codes to listed appliance amp draw data.
B. Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For
others, calculate/verify correct breaker size according to appliance amp draw rating
and type of breaker used.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
FUSING
CIRCUIT
BREAKER
Dual Element
Time D elay
60 Hz 50 Hz
120 1ø 2 8.7 --- 15 15