American Dryer Corp. EURO-24 Clothes Dryer User Manual


 
10
C. DRYER ENCLOSURE REQUIREMENTS
Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of
twelve (12) inches (30.48 cm) above the dryer's outer top; eighteen (18) inches (45.72 cm) for steam dryers,
except along the front of the dryer which may be closed if desired.
NOTE: Allowances must be made for opening the control door.
NOTE: Air considerations are important for proper and efficient operation.
Dryers may be positioned side wall to side wall. However, a 1/16" (0.16 cm) minimum allowance must be made
for opening and closing of the control door. It is suggested that the dryer be positioned about two (2) feet (0.61
meters)away from the nearest obstruction for ease of installation, maintenance, and service (to be measured
from the back guard). Refer to the illustration above for details.
X = 12" (30.48 cm) minimum, 24" (60.96 cm) suggested for ease of maintenance.
* 1" (2.54 cm) maximum for electric dryers.
** 18" (45.72 cm) minimum for steam dryers.