American Dryer Corp. EURO-12 Clothes Dryer User Manual


 
19
NOTE: A CIRCUIT SERVICING EACH DRYER
MUST BE PROVIDED.
1) Single-Phase (1ø) Wiring Connections/Hookup
The electrical input connections on ALL single-phase
(1ø) gas model dryers and steam model dryers are
made into the rear service box located at the upper
left area of the dryer.
2) Electric Models ONLY
ALL electrically heated dryers must be connected to the electric service shown on the dryer’s
data label which is affixed to the left side panel area behind the top control (access) door. The
connecting wires must be properly sized to handle the rated current.
NOTE: Electrically heated service (amperage) specifications/requirements are not available at the time
of printing. Contact factory for update.
NOTE: Component failure due to improper voltage application will VOID THE WARRANTY.
3. Grounding
A ground (earth) connection must be provided and installed in accordance with state and local codes. In
the absence of these codes, grounding must conform to applicable requirements of the National Electrical
Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable
Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The
ground connection may be to a proven earth ground at the location service panel.
IMPORTANT: For personal safety and proper operation, the dryer must be grounded.
Provisions are made for ground connection in each dryer at the electrical service connection area.
4. Electrical Connections
A wiring diagram is located inside the control box for connection data.
a. Gas Models and Steam Models ONLY