3. The dryer must be installed with provisions for adequate combustion and make-up air supply.
CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every
6 months, inspect the exhaust ducting and remove any lint build up.
C. DRYER ENCLOSURE REQUIREMENTS
Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of
6-inches (15.24 cm) above the dryer outer top, except along the front of the dryer which may be closed in if
desired.
LEAVE 18”-24” AT REAR OF DRYER
FOR MAINTENANCE & SERVICE
Dryers may be positioned sidewall to sidewall. However, allowances should be made for the opening and closing
of the control and lint doors. It is suggested that the dryer be positioned about 2 feet (0.61 meters) away from the
nearest rear obstruction for ease of installation, maintenance, and service.
NOTE: Air considerations are important for proper and efficient operation.
0” MIN DISTANCE TO
COMBUSTIBLE MATERIALS