American Dryer Corp. AD-50V Clothes Dryer User Manual


 
52
C. Blower motor (only) is not operating...
1. Failed blower (squirrel cage fan) motor contactor (relay).
2. Failed blower (squirrel cage fan) motor.
D. Both drive motor and blower motors are not operating (indicator light is on)...
1. Fault with L1 termination at reversing timer (for REVERSING MODELS ONLY).
2. Failed drying timer.
E. Reversing drive motor operates in one (1) direction only, stops and restarts in same direction
(for REVERSING MODELS ONLY)...
1. Failed reversing contactor (relay).
2. Failed reversing timer.
F. Heating unit is not operating (ALL temperature selections)...
GAS MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment and/or failed.
b. Sail switch is not closing or fluttering...
1) Check blower (squirrel cage fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Tripped burner hi-limit circuit.
3. Tripped lint compartment manual reset (225º F [107º C]) safety thermostat circuit.
4. Failed heat selector switch.
ELECTRIC MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment and/or failed.
b. Sail switch is not closing or fluttering...
1) Check blower (squirrel cage fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Failed oven hi-limit circuit.