2. Water Connections:
The water connection is made to the 1” F.P.T. bushing of the electric water solenoid valve located at the
front lower left area of the dryer. The water solenoid valve has a 1/2” M.P.T. connection and a 1/2”
bushing is supplied to provide the minimum 1/2-inch supply (feed) line. Flexible supply line/coupling must
be used in effort to avoid damage to electric water solenoid valve.
WARNING: Water must be supplied to suppression system or dryer will not operate.
IMPORTANT: Flexible supply line/coupling must be used. Solenoid valve failure due to hard
plumbing connections will VOID THE WARRANTY. It is recommended that a
filter or strainer be installed in the water supply line.
Typical water supply ...
OPTIONAL MANUAL BYPASS
Provisions are made in the dryer suppression system for the installation of an optional manual bypass. Depending
on the model dryer, the connections for the manual bypass are made at the “T” or “four way” fitting located in
the outlet supply side of the water solenoid valve. The use and connections of this manual bypass are at the
option or discretion of the owner.