22
6. Be sure that ALL gas shutoff valves are in the open position.
7. Be sure ALL back guard panels and service box covers have been replaced.
8. Check the lint drawer to ensure that it is closed and secured in place.
9. Rotate the basket (tumbler) by hand to be sure they move freely.
I. PREOPERATIONAL TESTS
ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test
should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit.
1. Turn on electric power to the dryer.
Open ALL gas shutoff valves.
2. Computer System Operational Test
Coin Models / Non-Coin (Free Mode)
a. The liquid crystal display (L.C.D.) display(s) will display “READY, AMOUNT TO START” and the
amount needed to start the dryer (i.e., “25”), meaning that the dryer is available and 25¢ is required to
start it.
b. Insert the proper number of coins into coin acceptor. Once the correct amount needed to start the dryer
has been inserted, the L.C.D. display(s) will read “SELECT TEMPERATURE”.
c. Select temperature by pressing “HI”, “MED”, or “LO”. The cycle will start and the L.C.D. will display
the dry cycle selected and remaining time.
NOTE: The dryer can be stopped at any time by opening the main door. To restart the dryer, shut the
main door and press the desired setting.
NOTE: Selection (setting) changes can be made at any time during the drying cycle by opening and
closing the main door and then making a new selection.
3. Heat Circuit Operational Test
a. When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition
attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air
to be purged from the lines.
The dryer is equipped with a Direct Spark Ignition (DSI) system, which has internal diagnostics. If
ignition is not established, the heat circuit DSI module will lock out until it is manually reset. To reset the
DSI system, open and close main door and restart dryer (press desired temperature selection).
NOTE: During the purging period, check to be sure that ALL gas shutoff valves are open.