6. Extractors (washers) not performing properly.
7. Sail switch is fluttering ... restriction in exhaust.
8. Failed microprocessor temperature sensor ... temperature calibration is inaccurate.
9. Failed microprocessor controller (computer) ... temperature calibration is inaccurate.
10. Failed burner / oven hi-limit.
11. Failed basket (tumbler) hi-limit thermostat.
12. Lint accumulation in location exhaust system.
Q. Condensation on main door glass ...
1. Too long, undersized, or improperly installed duct work.
2. Exhaust back draft damper is stuck closed or partially closed.
3. Restriction in exhaust duct work.
R. Dryer is making scraping noise at basket (tumbler) wrapper area ...
1. Check for object(s) caught in the basket (tumbler) wrapper area.
2. Basket (tumbler) is out of proper alignment ...
a. Check both the vertical alignment and lateral alignment.
b. Check gap between the front panel and the basket (tumbler) front ... set screws may have come loose
and basket (tumbler) walked forwards or backwards.
3. Loose or broken basket (tumbler) tie rod.
4. Broken basket (tumbler) support.
S. Excessive noise and/or vibration ...
1. Dryer is not leveled properly.
2. Impellor (fan) out of balance or broken.
3. Loose basket (tumbler) tie rod.
4. Basket (tumbler) is out of adjustment, or adjustment bolts (hardware) loose.
5. Loose motor or motor mount assembly.