Alliance Laundry Systems CPD6C Washer/Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Operation
17
9001001
If there was a problem during heating in a step at the
end of the program, the control will show
“Temperature sensor error”. The temperature was
never reached in this cycle.
Possible Faults:
Bad temperature probe.
Wiring to electrical or steam heating relay has
failed.
Electrical heating elements or steam valve is
broken.
NOTE: If the cycle aborted, it may be due to a
temperature sensor error.
The control did not sense any pulses or the control
sensed wrong pulses from the rpm sensor.
Possible Faults:
Rpm sensor is broken.
Distance from rpm sensor to pulley is too large
(>2mm).
Bad motor.
V-belt is broken.
Problems with the inverter.
Wiring connection is bad.
An error occurred at the end of a spin stop or during
coast down, where the rpm sensor suddenly failed to
give output pulses.
Possible Faults:
Rpm sensor failure.
Rpm sensor dislocated (too far from pulley).
Broken V-belt.
Wiring disconnected.
Rotation
sensor error
Speed detection
error
Temperature
sensor error