Alliance Laundry Systems SWD439C Clothes Dryer User Manual


 
Installation
800937
20
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Figure 25
DO NOT OPERATE OTHER APPLIANCES ON
THE SAME CIRCUIT. DO NOT OVERLOAD
CIRCUITS!
Do not operate both a washer and gas dryer on the
same circuit. Use separately fused 15 Amp circuits.
Electric Dryer
(120/240 Volt, 60 Hertz, 3-Wire Installation)
(120/208 Volt, 60 Hertz, 3-Wire Installation)*
*Alternative Heating Element Required
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
D799I
1 L1
2 Ground
3 Neutral Side
4 Round Grounding Prong
5 Neutral
1
3
4
2
120 ± 12
V.A.C.
0
V.A.C.
120 + 12
V.A.C.
STANDARD 120 VOLT, 60 HERTZ, 3-WIRE
EFFECTIVELY GROUNDED CIRCUIT
5
To reduce the risk of electric shock or fire,
DO NOT use an extension cord or an
adapter to connect the washer to the
electrical power source.
W031
WARNING
To reduce the risk of fire, electric shock or
personal injury, all wiring and grounding
MUST conform with the latest edition of
the National Electrical Code ANSI/NFPA 70
or the Canadian Electrical Code, CSA
C22.1, and such local regulations as might
apply. It is the customers responsibility to
have the wiring and fuses checked by a
qualified electrician to make sure the
laundry room has adequate electrical
power to operate the dryer.
W035
WARNING